Skip to the content
BATTERYCROSS Cell cross-reference, drawn to size

Index / 3-335WC

3-335WC

3-335WC — alkaline, 1.5 V, 25.2 x 50 mm, known as a C cell. Not listed by Energizer, and nothing in its catalog shares this size.

Nominal1.5V
Diameter25.2mm
Height50mm
Capacity8350mAh
In the Energizer catalogNot listed

Unlisted, and the near misses are all the wrong depth

This catalog holds nothing at 25.2 x 50 mm. What shares the diameter is out of production too, and all of it misses on depth: 2 cells run from 46.7 to 49.2 mm tall against this one's 50 mm, so every one of them stands off the contact, and none of them is too tall.

The household slot this size sits in

3-335WC is a C, which is a shape rather than a specification: 7 designations share the same slot in the Energizer data this site reads under different chemistries. This one is alkaline at 8350 mAh. Across the C the published capacity runs from 8350 mAh (3-335) to 2200 mAh (1.2H3). The compartment does not change; the run time changes by 3.8x.

The other chemistries in this slot are carbon zinc and nickel-metal hydride, and only the label says which one is in your hand. An alkaline cell left in a device it is not powering is the commonest way this size ruins equipment: the leak happens on the shelf, not under load. Energizer files it for North America, which is where the part is sold rather than where the cell will work.

  • Energizer no longer lists 3-335WC at all, so whatever goes into that compartment next will be a substitution rather than a replacement.

Drawn to scale

25.2 mm50 mm4.2 px per mm

3-335WC, side elevation, from the published figures

3-335WC3-3356F244.2 px per mm

The same scale for all of them. The dashed line marks the height of 3-335WC: a silhouette that stops short of it will not reach the contact, one that crosses it will not let the cover close.

This cellAnother cell, same scale

Every published figure

10 figures are published, and one is not: impedance. The row is absent rather than estimated. It reached shelves as 3-335WC.

Designation3-335WC
ChemistryAlkaline
Nominal voltage1.5 V
Diameter25.2 mm
Height50 mm
Weight65.5 g
Volume25 cc
Capacity8350 mAh to 0.8 V
Stored energy12525 mWh
Energy density501 mWh per cc
In the Energizer catalogNo longer listed
Listed forNorth America

2 rows in the table are not the maker's but ours: stored energy and energy per cubic centimeter. Everything else is reproduced without change.

What the maker says about cold

The sheet for 3-335WC carries an operating range as well as a capacity, and it reaches -18 C (-0 F) at the cold end. 3 more published figures follow it, and none of them reaches a cross-reference table.

The part occupies 25 cubic centimeters and weighs 65.5 g. Capacity and voltage together put 12525 milliwatt-hours in that space. Energizer files it for North America.

Operating range
-18 C (-0 F) to 55 C (131 F). Below the lower figure the maker makes no claim at all, which is not the same as the cell stopping.
Cutoff voltage
0.8 V. The published capacity is counted down to this voltage; a device that quits higher up sees less than the whole figure.
Mass against volume
65.5 g filling 25 cubic centimeters. When the printing has worn off, a kitchen scale separates two cells of one envelope faster than a caliper does.
Where the part is filed
North America. That is a statement about the maker's distribution and not about where the cell works.

Is that a lot of energy?

Nothing else measured shares this shell, so the comparison has to go site-wide: 12525 milliwatt-hours in 25 cubic centimeters is 501 mWh per cc, denser than 85% of every cell measured here. Density is ours: the maker publishes capacity and volume and never divides one by the other.

More energy per cubic centimeter than most

3-335WC packs more into its volume than most of what is measured here: 501 milliwatt-hours per cubic centimeter, above 85 percent of the corpus.

0 of those ones are still listed. Its 501 milliwatt-hours per cubic centimeter sit above 85 percent of everything here that publishes both a capacity and a volume. 36 of the 69 cylinders share its 1.5 V exactly.

  • 3-335 — the next step down by volume: 23.4 cubic centimeters against this cell's 25.
  • 3-335NNCI — the next step up: 25.2 cubic centimeters, 101% of this one.
  • 6F24 — 25.4 x 49.2 mm, 9 V, carbon zinc.
  • 3-335 — 25.2 x 46.7 mm, 1.5 V, alkaline.

Nothing else is stamped on this one

Nothing else is printed on 3-335WC in the Energizer data this site reads: one designation, no trade marking, no maker's part number, and no long form in the standard's table. A cell measuring 25.2 x 50 mm carries its whole identity in 7 characters.

The cell that differs only in depth

The code says the size, so the cells that get confused with 3-335WC are the ones that keep its diameter and change its depth. 2 cells share this diameter at depths from 46.7 to 49.2 mm, and every one of them enters the same opening.

It stands 1 of 1 in this envelope by stored energy. On a scale the difference shows before it shows on a caliper: this one weighs 65.5 g.

  • 3-335 — same diameter, 46.7 mm tall against this cell's 50: 3.3 mm shallower, which neither designation carries.
  • 6F24 — same diameter, 49.2 mm tall against this cell's 50: 0.8 mm shallower, which neither designation carries.
  • 1.2H3 — 26.2 mm across at 1.2 V against 25.2 mm here, 1 mm apart: too wide to enter in this holder.
  • 3-335I — 26.2 mm across at 1.5 V against 25.2 mm here, 1 mm apart: too wide to enter in this holder.
  • 1.2H3 — sold as the same C and rated 1.2 V against this cell's 1.5 V.

One figure the maker does not publish

One field is empty for 3-335WC: impedance. A blank means the maker publishes no figure, which is not the same as zero, and it is the reason one comparison below is missing rather than wrong.

The blanks are the same in all 1 record behind this designation, so they are the catalog's silence and not a merge losing a value. What is not missing is the envelope: 25.2 x 50 mm, published and checked against the designation itself.

  • No impedance — so this page cannot tell you whether the cell can drive a pulse, which is the whole question in a watch or a sensor.

Before you swap anything

Everything here is computed from published dimensions and nominal voltages. That answers whether a cell enters the compartment and whether the voltage matches on paper. It does not answer what your device does with the difference, and it cannot: a cell that fits can still be the wrong cell.

One more limit, and it is the biggest. This site reads a single manufacturer’s catalog. When a page says a designation is not listed, that means Energizer no longer offers a part under it — not that nobody makes the cell. Other makers may still sell it, and for common sizes they usually do.

A voltage difference is one relation between two cells, and this page prints it from the cell it is about — in every table on the page, including the one listing cells no longer made. A figure always belongs to the cell whose voltage is printed beside it: a cell that runs lower than this one carries a minus here, one that runs higher carries a plus, and two cells at the same nominal voltage carry zero. Meet the same pair on the other cell’s page and the sign is the other one, with the figure taken against that cell instead of this one; where the two run at the same voltage, both pages print zero. The class beside the figure is not read off that figure directly. It is decided on the gap itself, taken against the higher of the two nominal voltages, so one pair of cells gets one class whichever page you meet it on: counted from this side the boundary of the class that still runs falls at 20.0% below and 25.0% above, which is the same gap divided once by the larger nominal and once by the smaller. What genuinely differs between the two directions is the consequence, and the words carry it: a cell that runs low makes a calibrated instrument read below true, and a cell that runs high makes it read above.

3 things this site cannot see. Whether the contacts reach a shorter cell. Whether the device was calibrated for a chemistry that holds its voltage flat, which silver oxide does and alkaline does not. Whether the equipment tolerates the higher current a different chemistry can deliver. Rechargeable cells are never a drop-in for primary cells regardless of size.

Cells measured next to this one

Nothing in the Energizer data on this site shares this exact size. The 2 cells below have the same diameter and a different depth — 46.7 to 49.2 mm against this cell's 50 — which is a near miss rather than an alternative.

  • 3-335 — 25.2 x 46.7 mm, 1.5 V
  • 6F24 — 25.4 x 49.2 mm, 9 V

Where these numbers come from

Dimensions, voltages, chemistries and capacities are published by the manufacturer and reproduced without change. Everything else on the page is ours, computed from those figures: whether one cell fits where another sat, how far apart their voltages are, stored energy and energy per cubic centimeter, the rank within a shell, and the check of the designation against the measured size.

Fit is decided within 0.3 mm on every axis, which is the order of a contact spring's travel. Voltage classes are decided by consequence, not by roundness, and they are decided on the gap between two nominal voltages taken against the higher of the two: 2.0% or less of it is the same working voltage, 6.0% starts to matter to a calibrated instrument, and past 20.0% it is a different class altogether. Measuring the gap against the higher figure is what makes the verdict the same from either cell’s page, while the printed percentage stays counted from the cell you are reading about. Cells with identical stored energy share a rank instead of being ordered arbitrarily.

Ranking uses capacity times nominal voltage, because capacity alone is not comparable across chemistries: 150 mAh at 3 V is twice the energy of 150 mAh at 1.5 V. Neighbors are chosen by measurement and never alphabetically, because two cells filed next to each other by name usually have nothing in common. A blank in any table means the maker publishes no figure, which is not the same as zero.

Source: Energizer technical data, retrieved 1 September 2026.

The record behind this page

Every figure on this page comes from one catalog record, number 453, and it is linked below. The sheet is the document the dimensions, voltage and capacity were read out of.

  1. [1] Energizer catalog record 453, obsolete in the snapshot. Technical data sheet: 3-335wc.pdf.

Every figure above is reproduced from those records without change; the comparisons are ours and are described on the method page. Snapshot: Energizer technical data, retrieved 1 September 2026.

Putting this on a forum or a repair page? The same answer without the site around it — fit, voltage, chemistry and the limits that go with them — is at /embed/3-335wc/. It loads nothing from anywhere else. Paste this:

<iframe src="https://batterycross.com/embed/3-335wc/" width="100%" height="520" loading="lazy" title="3-335WC replacements"></iframe>